XLi Time & Frequency System 103
XLi-man, Issue 8, 6/17/2008, Rev. H
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
3 = ASCII character 3
<SP> = ASCII space character one or more.
<SEP> = one or more separators characters, space, tab, or comma.
S = ASCII character S, Status delimiter
<STATUS> = 'L' Locked
'U' Unlocked
<SOURCE> = 'A' Clock IRIG A
'B' Clock IRIG B
'N' lock NASA 36
'P' Clock Primary
'S' Clock Secondary
'R' Clock to Aux Ref
'F' None
1 = '-' PLL Synthesizer Locked
'C' PLL Synthesizer Unlocked
2 = '-' LPN PLL Locked
'L' LPN PLL Unlocked
3 ='-' Primary OK
'P' Primary Fault
4 = '-' Secondary OK
'S' Secondary Fault
5 = '-' IRIG OK
'I' IRIG Fault
6 = '-' Aux Ref OK
'A' Aux Ref Fault
7 = '-' Primary Power OK
'W' Primary Power Fault
8 = '-' Secondary Power OK
'w' Secondary Power Fault
9 = '-' Rb oscillator OK
'R' Rb oscillator Fault
A = '-' DAC OK
'X' DAC Fault
B = '-' First time lock OK
'a' Clock Status has locked since power on but still within the user defined power
on time out
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com