104 XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
To see the states the Alarm Latches for all of the indicators, enter:
F73<S>LATCH<CR>
XLi replies:
F73<S>LATCH<SEP><123456789ABCDEFGHIJ><CR><LF>
To clear the Alarm Latches, enter:
F73<S>CLEAR<SEP>ALARM<SEP>LATCH<CR>
XLi replies:
OK
The command line uses a ‘mask’ to enable or disable each indicator’s alarm. To see which indicators are
Alarm Enabled, enter:
F73<S>MASK<CR>
XLi replies:
F73<S>MASK<SEP>M<12346789ABCDEFGHIJ><CR><LF><LF>
where:
'A' Clock Status has not locked since power on
C = '-' Time error OK
'U' Time error Fault
D = '-' Timeout OK
'T' Timeout Fault
E ='-' NTP OK
'N' NTP Fault
F Future Use
G Future Use
H Future Use
I Future Use
J Future Use
‘E’ = enabled
‘D’ = Disabled