110 XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
<SP> = ASCII space character one or more.
B = ASCII character to denote Option Bay number follows
<N> = Option Bay Number, 1 through 10.
TM = ASCII character for TM selection request
<LT> = line terminator; for output strings (a carriage return and line feed ) or for input strings (a
carriage return only).
Sample request: F77 B2 TM<CR><LF>
Response: F77 B2 TM LOCAL <CR><LF>
To change the PTTI Output option card BCD Time Mode selection, send the following send the following
string to the Serial/Network port:
F77<SP>B<N><SP>TM<SP><OUT><LT>
where:
F = ASCII character F.
77 = function number.
<SP> = ASCII space character.
B = ASCII character to denote Option Bay number follows
<N> = Option Bay Number, 1 through 10.
TM = ASCII character to denote “Time Mode” selection.
<OUT>= UTC, LOCAL, STANDARD or GPS.
<LT> = line terminator; for output strings (a carriage return and line feed ) or for input strings (a
carriage return only).
Sample entry: F77 B2 TM LOCAL<CR>
Response: OK<CR><LF>