XLi Time & Frequency System 111
XLi-man, Issue 8, 6/17/2008, Rev. H
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
To obtain the PTTI Output option board BCD output format information, send the following string to the
Serial/Network port:
F77<SP>B<N><SEP>BCD<CR><LF>
where:
F = ASCII character
77 = function number.
<SP> = ASCII space character one or more.
B = ASCII character to denote Option Bay number follows
<N> = Option Bay Number, 1 through 10.
BCD = ASCII character for BCD output format request
<LT> = line terminator; for output strings (a carriage return and line feed ) or for input strings (a
carriage return only).
Sample request: F77 B2 BCD<CR><LF>
Response: F77 B2 BCD ABBREV <CR><LF>
To change the PTTI BCD output selection, send the following send the following string to the Serial/
Network port:
F77<SP>B<N><SP>BCD<SP><OUT><LT>
where:
F = ASCII character F.
77 = function number.
<SP> = ASCII space character.
B = ASCII character to denote Option Bay number follows
<N> = Option Bay Number, 1 through 10.
BCD = ASCII character to denote “Binary Coded Decimal” selection.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com