XLi Time & Frequency System 265
XLi-man, Issue 8, 6/17/2008, Rev. H
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
"TRUE, if a primary reference clock fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 3 }
faultSecondaryRefClk OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a secondary reference clock lock fault occurred since the
fault latch was cleared."
::= { systemFaultHistory 4 }
faultIrig OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if an IRIG lock fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 5 }
faultAuxRef OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if an auxiliary reference clock fault occurred since
the fault latch was cleared."
::= { systemFaultHistory 6 }
faultPrimaryPower OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a primary power fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 7 }
faultSecondaryPower OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a secondary power fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 8 }
faultRbOsc OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com