266 XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
"TRUE, if a rubidium oscillator fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 9 }
faultDac OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a digital to audio converter fault has occurred since the
fault latch was cleared."
::= { systemFaultHistory 10 }
faultFirstTimeLock OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if the system clock has failed to lock since power on and the
latched faults have not been cleared."
::= { systemFaultHistory 11 }
faultTimeError OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a time error fault occurred since the fault latch was
cleared."
::= { systemFaultHistory 12 }
faultTimeout OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a timeout fault occurred since the fault latch was
cleared."
::= { systemFaultHistory 13 }
faultNtp OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if NTP was in an alarm since the fault latch was cleared."
::= { systemFaultHistory 14 }
statusClock OBJECT-TYPE
SYNTAX INTEGER {
locked(1),
unlocked(2)
}
MAX-ACCESS read-only
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XLi and is the answer not in the manual?

Symmetricom XLi Specifications

General IconGeneral
BrandSymmetricom
ModelXLi
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals