XLi Time & Frequency System 71
XLi-man, Issue 8, 6/17/2008, Rev. H
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
F42<S>B<N>O<S><C><CR>
where
For example, to request the time code on board 1, output 1, enter:
F42 B1O 1<CR>
Or, optionally:
F42 B1 O1<CR>
The XLi responds with the time code of the output:
F42 B1 1 IRIG-B 120<CR><LF>
If the time code is IRIG-A or IRIG-G, the response includes a parenthetical reminder that all outputs set
to that time code (e.g., IRIG G) are also set to the same time code type (e.g., 141):
F42 B1 1 IRIG-G 141(ALL "G" PORTS)
Setting the time code of a specific output port
Use the following format to set the time code for a specific output port:
F42<S>B<N><S>O<S><C><S><CODE><CR>
F42 = ASCII string representing the Function Number
<S> = one or more separator characters, space, tab or comma
B = ASCII character indicating board number to follow
<N> = the board number, 1 to 10
O = ASCII letter “ohh” indicating output port (not zero)
<C> = output number, 1 to 4
<CR> = carriage return
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com