72 XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
where:
For example, to set board 1, output 1, to IRIG-B 123, enter:
F42 B1 O 1 IRIG-B 123<CR>
The XLi responds:
OK<CR><LF>
Setting a port to IRIG-A switches all output ports set to IRIG-A to the same IRIG-A type (e.g., IRIG-A
133). The same is true for IRIG-G. Therefore the following example would set all of board 1’s IRIG-A
outputs, not just output 1, to IRIG-A 133 time code:
F42 B1 O 1 IRIG-A 133<CR>
The XLi responds:
OK<CR><LF>
Requesting the time reference of a specific board
Use the following format to request the Time Reference of a specific board:
F42<S>B<N>T<CR>
where
The XLi responds with the Time Reference for the selected board.
F42 = string representing the Function Number
<S> = separator
B = ASCII letter indicating board number follows
<N> = board number, 1 to 10
O = ASCII letter indicating output port
<C> = channel number, 1 to 4
<CODE> = IRIG-A 130, IRIG-A 133, IRIG-B 120, IRIG-B 123, IRIG-E 111, IRIG-E 112, IRIG-E 121, IRIG-E
122, IRIG-G 141, IRIG-G 142, IRIG-H 111, IRIG-H 112, IRIG-H 121, IRIG-H 122, 2137, XR3,
NASA 36
Note: A dash is required when entering IRIG types. NASA 36 is entered without a dash. 2137 and
XR3 have no dashes or spaces when entered.
<CR> = Carriage Return
<N> = board number, 1 to 10.
<S> = ASCII space character.
T = ASCII letter requesting Time Reference.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com