Table 7-3: Voltage Programming Range
Table 7-4: Current Programming Range
Model
Rated Output
Voltage (V)
Minimum
(V)
Maximum
(V)
Model
Minimum
(A)
Maximum
(A)
8
0.000
8.000
GEN6-100
000.00
100.00
10
00.000
10.000
GEN8-90
000.00
90.00
15
00.000
15.000
GEN12.5-60
000.00
60.000
20
00.000
20.000
GEN20-38
00.00
38.000
30
00.000
30.000
GEN30-25
00.00
25.000
40
00.000
40.000
GEN40-19
00.00
19.000
60
00.000
60.000
GEN60-12.5
00.000
12.500
80
00.000
80.000
GEN80-9.5
00.000
9.500
100
000.00
100.00
GEN100-7.5
00.000
7.500
150
000.00
150.00
GEN150-5
00.000
5.000
300
000.00
300.00
GEN300-2.5
0.000
2.500
600
000.00
660.00
GEN600-1.3
0.000
1.300
Table 7-5: Not Used
Table 7-6: OVP Programming Range
Table 7-7: UVL programming range
Model
Rated Output
Voltage (V)
Minimum
(V)
Maximum
(V)
Model
Rated Output
Voltage (V)
Minimum
(V)
Maximum
(V)
6
0.5
7.50
6
0
5.70
8
0.5
10.0
8
0
7.60
12.5
1.0
15.0
12.5
0
11.9
20
1.0
24.0
20
0
19.0
30
2.0
36.0
30
0
28.5
40
2.0
44.0
40
0
38.0
60
5.0
66.0
60
0
57.0
80
5.0
88.0
80
0
76.0
100
5.0
110.0
100
0
95.0
150
5.0
165.0
150
0
142
300
5.0
330.0
300
0
285
600
5.0
660.0
600
0
570
7.9 Fast Queries
These are commands that read a response very quickly from the power supply. They use
unprintable character codes. They allow the power supply to avoid the normal command
processing delays.
The processing time for these queries is typically 2 mSec, so total query speed is 2 mSec
plus the RS232/RS485 transmission time.
Since these queries embed the power supply address (0 to 30), there is no need to first
send the “ADR n addressing command.
NOTE:
The power supply can accept values higher by 5% than the table values, however, it is
not recommended to program the power supply over the rated values.