6. TERMINAL FILE PROGRAMMING
EO3-11106
6.25 PLU Preset-Code Key Setting
6-126
(continued from the previous page)
Operation LCD Display Remarks
Depress the [] key.
The cursor is moved on to “2 PLU CODE
KEY”.
Depress the [2] or [Enter] key.
2 PLU CODE KEY” is selected.
Input 55, then depress the [Enter] key.
(Key Location Code 55 is set.)
On this screen, when inputting a PLU code
then depressing a PLU preset-code key, the
[PLU] key setting is possible. In this case,
the PLU preset-code keys on the standard
flat type keyboard can be set. The other
keys should be set with the key location
code.
Input 1111, then depress the [Enter]
key.
(PLU Code 1111 is set.)
The display returns to the key location
code input screen.
The [End] key depression allows the
ECR to end this setting.
A long receipt is issued and the display
returns to Main Menu screen.
(2) To assign PLU Code 1111 on the PK-2 keyboard.
Operation LCD Display Remarks
When the ECR is being outside a sale
and in SET mode, depress the [] key
twice.
The cursor is moved on to “3 DP/PLU”.
Depress the [3] or [Enter] key.
3 DP/PLU” is selected.