Loading...
4-101
Table 4.4.4 Multi-function digital input setting (03-00 ~ 03-05) (“O”: Enable, “X”: Disable)
Value
Function
Description
Control mode
Name LCD Display V/F SLV
PM
SLV
0
2-wire type
(Forward
operation)
2-Wire
(FWD-RUN)
2- wire (ON : Forward operation
command).
O O O
1
2-wire type
(Reverse
operation)
2-Wire
(REV-RUN)
2- wire (ON : Reverse operation
command).
O O O
2
Multi-Speed
Setting Command
1
Muti-Spd Ref 1
Multi-Speed Reference 1
O O O
3
Multi-Speed
Setting Command
2
Muti-Spd Ref 2
Multi-Speed Reference 2
O O O
4
Multi-Speed
Setting Command
3
Muti-Spd Ref 3
Multi-speed Reference 3
O O O
5
Multi-Speed
Setting Command
4
Muti-Spd Ref 4 Multi-speed Reference 4 O O O
6
Forward Jog Run
Command
FJOG
ON: Forward operation in jog mode
(00-18)
O O O
7
Reverse Jog Run
Command
RJOG
ON: Reverse operation in jog mode
(00-18)
O O O
8
UP Frequency
Increasing
Command
UP command
ON: Command of output frequency
increasing (only used by support of
DOWN command).
O O O
9
DOWN Frequency
Decreasing
Command
DOWN
command
ON: Command of output frequency
decreasing (only used by support of
UP command).
O O O
10
Acceleration/
Deceleration
Setting Command
1
A
cc/Decel Time
Selection 1
Acceleration/deceleration time selection
command1
O O O
11
Acceleration/
Deceleration
Inhibition
Command
ACC/DEC
Inhibit
ON: Acceleration/deceleration prohibition O O O
12
Main/Alternative
Run command
Switching
Run Change
Sel
Run command source is set by alternative
run command (00-03).
O O O
13
Main/Alternative
Frequency
Command
Switching
Freq Change
Sel
Frequency command source is set by
alternative frequency command (00- 06).
O O O
14
Emergency Stop
(Decelerate to
Zero and Stop)
E-Stop ON: Emergency stop input O O O
15
External
Baseblock
Command
(Rotation freely to
Stop)
Ext. Baseblock ON: Inverter base interdiction O O O
16
PID Control
Disable
PID Disable ON: PID control disable O O O
17 Fault Reset Fault Reset Fault reset O O O
18 Reserved Reserved Reserved - - -
19
Speed Search
1(from the
maximum
frequency)
Speed Search
1
ON: Search the speed from the maximum
output frequency
O O X

Table of Contents

Other manuals for TECO F510 series