4-116
Value
Function
Description
Control Mode
Name LCD Display V/F SLV
PM
SLV
6
Automatic
Restart
Auto Restart ON: the period of automatic restart O O O
7~8 Reserved Reserved Reserved - - -
9 Baseblock Baseblock ON: During baseblock O O O
10~11 Reserved Reserved Reserved - - -
12
Over-Torque
Detection
Over Torque ON: Over torque detection is ON O O O
13 Current Agree Current Agree ON: Output current > 03-15 O O O
14
Mechanical
Brake Control
(03-17~03-18)
Mechanical
Brake Control
ON: Mechanical brake release frequency
OFF: Mechanical brake operation frequency
O O O
15~17 Reserved Reserved Reserved - - -
18 PLC Status
PLC
statement
ON: when 00-02 is set to 3 (PLC operation
command source)
O O O
19 PLC Control
Control From
PLC
ON: Control from PLC O O O
20 Zero Speed Zero Speed
ON: Output frequency < Minimum output
frequency (Fmin)
O O O
21 Inverter Ready Ready ON: Inverter ready (after power on, no faults) O O O
22
Undervoltage
Detection
Low Volt
Detected
ON: DC bus voltage = < Low-voltage warning
detection level (07-13)
O O O
23
Source of
Operation
Command
Run Cmd
Status
ON: Operation command from LED digital
operator (local mode)
O O O
24
Source of
Frequency
Command
Freq Ref
Status
ON: Reference frequency from LED digital
operator (local mode)
O O O
25
Low Torque
Detection
Under Torque ON: Low-torque detection is ON O O O
26
Frequency
Reference
Missing
Ref. Loss. ON: Reference frequency loss O O O
27
Timing Function
Output
Timer Output
Set time function parameter to 03-37 and
03-38and the time function input is set by
parameter from 03-00 and 03-05
O O O
28~31 Reserved
Reserved
Reserved - - -
32
Communication
Control
Contacts
Control
From Comm
ON: DO is set by communication control. O O O
33 RTC Timer 1 RTC Timer 1
ON: 16-36 (RTC Speed Selection) selects
Timer 1 and 16-32 (Source of Timer 1) is
active in the set time.
O O O
34 RTC Timer 2 RTC Timer 2
ON: 16-36 (RTC Speed Selection) selects
Timer 2 and 16-33 (Source of Timer 2) is
active in the set time.
O O O
35 RTC Timer 3 RTC Timer 3
ON: 16-36 (RTC Speed Selection) selects
Timer 3 and 16-34 (Source of Timer 3) is
active in the set time.
O O O
36 RTC Timer 4 RTC Timer 4
ON: 16-36 (RTC Speed Selection) selects
Timer 4 and 16-35 (Source of Timer 4) is
active in the set time.
O O O
37
Detection
Output of PID
Feedback Loss
PID Fbk Loss ON: PID Feedback Loss O O O