4-144
04-05=14: Positive / negative torque limits
Multi-function analog input AI2 can be used to adjust both the positive and negative torque limit.
For more details on torque limits, please refer to parameter group 21 - torque control group.
04-05=15: Reserved
04-05=16: Torque compensation of speed control
Multi-function analog input AI2 can be used to adjust the torque compensation in closed loop vector mode.
For more details on the torque control functions, please refer to parameter group 21 - torque control group.
04-11
AO1 Function Setting
Range
【0】:
Output Frequency
【1】: Frequency Command
【2】:
Output Voltage
【3】:
DC Voltage
【4】:
Output Current
【5】:
Output Power
【6】:
Motor Speed
【7】: Output Power Factor
【8】: AI1 Input
【9】: AI2 Input
【10】:
Torque Command
【11】: q-axis Current
【12】: d-axis Current
【13】: Speed Deviation
【14】:
Reserved
【15】:
ASR Output
【16】:
Reserved
【17】:
q-axis Voltage
【18】: d-axis Voltage
【19】~【20】: Reserved
【21】: PID Input
【22】: PID Output
【23】: PID Target Value
【24】: PID Feedback Value
【25】: Output Frequency of the Soft Starter
【26】: Reserved
【27】: Reserved
【28】: Communication Control
04-12
AO1 Gain
Range
【
0.0~1000.0】%
04-13
AO1 Bias
Range
【
-100.0~100.0】%
04-16
AO2 Function Setting
Range
Setting range and definition are the same as those of 04-11.
04-17
AO2 Gain
Range
【
0.0~1000.0】%
04-18
AO2 Bias
Range
【
-100.0~100.0】%
04-19
AO Output Signal Type