EasyManua.ls Logo

TECO JSDEP Series - Page 152

TECO JSDEP Series
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-14
Communication
Address
Parameter Name & Function Default Unit
Setting
Range
Control
Mode
RS232 RS485
Speed command smooth accel/decel time Constant.
Sn206
Set Sn205=1 to enable this function then set the time
period for the speed to rise to 63.2% of the full speed.
1 msec
1
10000
S 52BH 0206H
Speed command linear accel/decel time constant.
Sn207
Set Sn205=2 to enable this function then set the time
period for the speed to rise linearly to full speed.
1 msec
1
50000
S 52CH 0207H
S curve speed command acceleration and
deceleration time setting.
Sn208
Set Sn205=3 to enable this function.
In the period of Acc/Dec , drastic speed changing might
cause vibration of machine. S curve speed command
acc/dec time setting has the effect to smooth acc/dec
curve.
Rule for the setting
s
a
t
t
>
2
s
d
t
t
>
2
1 msec
1
1000
S C44H 0208H
S curve speed command acceleration time setting.
Sn209
Refer to Sn208
200 msec
0
5000
S C45H 0209H
S curve speed command deceleration time setting.
Sn210
Refer to Sn208
200 msec
0
5000
S C46H 020AH

Table of Contents

Other manuals for TECO JSDEP Series

Related product manuals