3-9              
 
Parameter 
Signal 
Display  Unit  Explanation 
Un-21 
Pulse command – 
rotation value(High Byte)
rev 
After power on, it displays pulse command input 
rotation number in High Byte value.  
Un-22 
Position feedback  pulse  2500/8192 ppr Encoder feedback (Absolute). 
Un-23 
Reserved  ─ Reserved 
Un-24 
Reserved  ─ Reserved 
Un-25 
Reserved  ─ Reserved 
Un-26 
Reserved  ─ Reserved 
Un-27 
Reserved  ─ Reserved 
Un-28 
Torque command  % 
It displays the torque command as a percentage of 
the rated torque.  
Ex: Display. 50.Means current motor torque 
command is 50% of rated torque.  
Un-29 
Load inertia   x0.1 
When Cn002.2=0(Auto gain adjust disabled), it 
displays the current preset load inertia ratio from 
parameter Cn025.  
When Cn002.2=1(Auto gain adjust enabled), it 
displays the current estimated load inertia ratio. 
Un-30 
Digital Output status(Do) ─ 
The status of digital output contact (Do) 
represented in hexadecimal. 
Ex : H00XX (0000 0000 Do-8/7/6/5 Do-4/3/2/1) 
Un-31 
Digital Input status(Di)  ─ 
The status of digital input contact (DI) represented 
in hexadecimal. 
Ex : HXXXX (000Di-13 Di-12/11/10/9 Di-8/7/6/5 
Di-4/3/2/1) 
Un-32 
Present Fault Monitor by 
modbus communication 
(only for modbus) 
-- -- 
Un-33 
Speed detection of fixed 
filtering (only for modbus)
-- -- 
Un-34 
Torque detection of fixed 
filtering(only for modbus)
-- --