Troubleshooting
Put
the
oscilloscope
in
XY
mode.
Turn
the
readout
intensity
all
the
way
down.
Select
CH2
and
vary
the
vertical
position
knob
while
measuring
the
voltage
across
J75
pins
3
and
1
01'176
and
W75
on
TAS 485)
with
a DMM
or
oscilloscope.
No
Press
the
CH1
button
and
rotate
the
vertical
position
knob
while
measuring
the
voltage
across
the
pins
16
and
17
of
J67
with a DMM
or
oscilloscope.
No
No
Note: In
XY
mode,
a
single
dot
should
appear
near
the
center
of
the CRT.
Reduce the intensity
until
the
spot
is
dim
so
that
the
CRT
phosphor
will
not
be
damaged.
Measure
the
voltage at the
base
(middle pin)
of
0361
while
adjusting the
focus
knob.
Perform
the
A 1
Analog
Board
Troubleshooting
Procedure.
Perform
the
A2 Display
Control
Board
Troubleshooting
Procedure.
Figure 6-23: A3 Display Driver Board Troubleshooting Procedure (Cont.)
6-46
Maintenance
Scan by Zenith

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TAS 475 and is the answer not in the manual?

Tektronix TAS 475 Specifications

General IconGeneral
BrandTektronix
ModelTAS 475
CategoryTest Equipment
LanguageEnglish

Related product manuals