TRIGGER Controls
THS710A, THS720A, THS730A & THS720P User Manual
3–61
Motor Trigger (THS720P)
Choose motor triggering to trigger on the rising or falling edge of a
bipolar, motor drive waveform.
S
PE
E
Trigger Type Motor
ME
Trigger Source Ch1
Ch2
Trigger
Coupling
DC
AC
Trigger Slope / (rising edge)
\ (falling edge)
Mode & Holdoff Auto
Normal
Set holdoff
Key Points
Trigger Level. You can set the trigger level from 0.1 to 5 divisions for
positive slope, and from –0.1 to –5 divisions for negative slope. If
you change the slope, the trigger level automatically changes sign.