Chapter 4 – Sprayer Controller Setup
25
4.5. Setting up the control valve
The control valve is used to meter/control the volume of product
discharged from the boom.
4.5.1. Regulator valve system
Regulator valve systems are placed in line with the pump and adjust the
flow of product to the boom by diverting excess flow back to the tank.
1.
Select Implement / Sprayer / Control Valve .
2. Select CONTROL VALVE and select Regulator.
l Flow meter sampling: Sets how frequently sampling is done.
Standard sampling is recommended. Reduced is recommended only
if flow may be highly irregular (for example, on worn equipment).
l Valve speed: Sets the speed at which the valve is driven to control
the rate.
l Close valve when off: Ensures that the valve is closed when the
tank is not in use. This closes the valve when the Master Switch is
off and/or when all sections are turned off.
l Reverse valve: In some sprayers the valve may have been wired to
work in the opposite direction. This setting allows the valve to
work in reverse.