Chapter 5 – Operation (X35/X30/X25)
41
1
Displays two parameters related to the specific tank. Selecting
opens a customize data window with a list of available parameters
to be displayed.
2
Requested application rate. Used to enter and display the
application rate. The control system uses the calibration factor to
adjust the product flow for the given product. This is disabled if
VRC is being used.
3
Increase/decrease requested application rate by preset rate
increment (increment is set by selecting button shown at 6).
4
Requested application rate presets. These are the user-defined
default application rates (set by selecting button shown at 6).
Selecting one of these icons adjusts the application rate to that
value.
5
Rate control mode selector. Allows you to select VRC or Auto
control for a specific tank or all products.
Manual may also be selected for all tanks (but not for a specific
tank). Note that Auto Section Control will not work in manual
mode. When in manual mode, the requested rate is greyed out and
the actual rate may be adjusted using the + and – buttons.
6
Product configuration. Opens the product configuration window
for the tank. Refer to Selecting / adding a product, page 43.
7
Tank fill. Opens the tank fill window to add volume of the
product being used. Refer to Filling tanks, page 45.
8
Tank metering on/off toggle. Green when tank is on (metering
running), red when tank is off (metering stopped).
9
Displays up to five parameters related to the specific tank. Opens a
customize data window with a list of available parameters to be
displayed.