Net-G3A Configuration and Setup
NET-G3A Operator’s Manual
3-16
MINTER Operation
To turn on/off the receiver, press the power button (Figure 3-12).
• When turning on, press the power button until the MINTER’s
LEDs briefly flash.
• When turning off, press the power button until the PWR LEDs
turn red, then release.
Figure 3-12. Power Button Functions
To start/stop logging data, press the FN button for 1 to 5 seconds
(Figure 3-13).
• During data recording, the REC LED is green. Use PC-CDU to
set the recording time interval. See “Recording Interval
parameter” on page 3-11 for details.
• The REC LED blinks green each time data is written to the
receiver’s memory.
• If the REC LED is red, the receiver has run out of memory, has a
hardware problem, or contains an improper OAF (see “Option
Authorization File (OAF)” on page 1-21 for more information).
Use PC-CDU to enable the desired FN key mode in the receiver,
either “LED blink mode switch” for static surveys or “Occupation
mode switch” for kinematic surveys. See “FN Key Mode parameter”
on page 3-13 for details.
FN
STAT LINK PWR 1
REC RX/TX PWR 2
A
Power ButtonPress the power button for about 1
second to turn the receiver on/off.
Net-G3A_OM_Book.book Page 16 Thursday, May 14, 2009 8:49 AM