Troubleshooting
Topcon Paver System Five Operator’s Manual
9-10
Control Box Symptom 12
“The Control Box displays ‘No Signal’ when indicate is
selected in elevation mode.
Probable Cause
Sonic Tracker is reporting no echo.
1. Verify that the Sonic Tracker is ticking.
2. Make sure tracker is pointing at a target with the
working range, recommended 14 to 24 inches.
3. Transducer may be dirty or damaged. Refer to the
Transducer and Filter section within this manual.
4. Power or ground connection at transducer may be
loose. Remove transducer and check wires.
Control Box Symptom 13
“The Auto light on the Control Box intermittently flashes on
and off.
Probable Cause
Sonic Tracker is too far from reference for current
atmospheric conditions, or Temperature Cutout is too low.
1. Verify that the Sonic Tracker is positioned 14 to 24
inches from the reference. If there are gusty winds
lower the Tracker to 14 to 16 inches from the reference.
2. Move Tracker away from gusty heat source, such as
engine fan exhaust.
3. Temperature Cutout is set too low. Factory setting is 7.
Refer to Technicians manual.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon Paver System 5 and is the answer not in the manual?

Topcon Paver System 5 Specifications

General IconGeneral
BrandTopcon
ModelPaver System 5
CategoryControl Systems
LanguageEnglish

Related product manuals