Slope Sensor Symptoms
P/N 7010-0341 www.topconpositioning.com
9-15
2. Verify that the slope cable is connected securely and
properly.
3. Swap slope cable from other side to check cable.
Slope Sensor Symptom 2
“Cross Slope drives cylinder in the wrong direction.
Probable Cause
Slope sensor installed incorrectly.
1. Verify the slope sensor is positioned correctly on the
transverse beam. “Slope Forward” Decal must be in
direction of travel.
2. Check that the machine is properly wired and
hydraulically connected to the valve. Raised jog switch
should make the cylinder go up, lower jog switch
should make the cylinder go down. Refer to the paver
manufacturers manual.
Slope Sensor Symptom 3
“Slope lights flash between raise and lower and will not stay
On-Grade.
Probable Cause
Incorrect Performance Setting adjustments or a loose
transverse beam.
1. Check Valve Offset for proper operation. Refer to
“Setting Valve Offsets” section in this manual.
2. Check gain setting. Factory setting is 25.
3. Slope deadband set too low. Increase Slope Deadband.
Factory Setting is .075%.
4. Check for excess vibration in the Transverse Beam due
to poor connection at Tow Arm.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon Paver System 5 and is the answer not in the manual?

Topcon Paver System 5 Specifications

General IconGeneral
BrandTopcon
ModelPaver System 5
CategoryControl Systems
LanguageEnglish

Related product manuals