Greensmaster 3250--D
Page 5 -- 7
Electrical System
Starting Problems (continued)
Problem Possible Causes
Engine cranks (but should not) with
the functional control lever in the
MOW or TRANSPORT position.
Neutral sensor is out of adjustment.
Neutral sensor or circuit wiring is faulty.
Interlock relay or circuit wiring is faulty.
Engine cranks, but does not start. Wiring to start circuits is loose, corroded or damaged (see Electrical
Schematic in Chapter 9 -- Foldout Drawings).
Run relay or circuit wiring is faulty.
High temperature relay or circuit wiring is faulty.
High temperature switch or circuit wiring is faulty.
Fuel solenoid or circuit wiring is faulty.
Glow plugs, glow relay or glow controller are faulty.
Engine or fuel system is malfunctioning (see Chapter 3 -- Diesel
Engine).
Engine and fuel may be too cold.
Engine cranks (but should not) with
the Functional Control Lever in the
MOW or TRANSPORT position.
Neutral sensor is out of adjustment or faulty.
Neutral sensor circuit wiring is faulty.
Electrical
System