Step3:TestthewiringforsolenoidSRV.
1.Removetherightsidecover.
2.Slidetheoperatorseatassemblyallthewaytowardtherearofthemachine.Thentilttheseatitselfforward.
3.LocatetheprimaryTEC-5001controller(Figure119).
g237658
Figure119
1.Rightfronttire3.PrimaryTEC-5001controller
2.Operatorseat4.Mountingbolts(2of4areshown)
4.RemovethefourmountingboltsthatsecuretheprimaryTEC-5001controller(Figure119).
5.LifttheprimaryTECupandoutofitsmountedlocation(Figure120).
6.Fullyloosenthesocket-headscrewthatsecuresmainharnessconnectorP01totheprimaryTEC(Figure
120)andthenunplugtheconnector.