11. Check for continuity between a slip ring and shaft
(core) (Fig. 55). Replace the field coil if there is
continuity.
Figure 55
12. Check for continuity between lead wires of the s
tator
coil (Fig. 56). Replace the stator coil if there is no
continuity.
Figure 56
13. Check for continuity between each lead wire a
nd
stator core (Fig. 57). Replace the stator coil if there is
continuity.
Figure 57
Reelmaster
®
5100-D Page 5 - 43 Repairs