SETTING / ADJUSTMENT
6 - 40
6.7 Image Quality Adjustment (FAX Function)
6.7.1 Density adjustment
The center density and the density variation controlled by density adjustment keys can be adjusted as
follows.
<05 Adjustment Mode>
* Since the gradation in this mode is reproduced in a binary image (black and white), this adjustment
should be a simple binary threshold adjustment.
<Procedure>
(1) Performs FS-05.
(2) Key in a code and press the [START] button.
(3) Key in an adjustment value.
(To correct the value once keyed in, press the [CLEAR] button.)
(4) Press the [OK] button to store the value. The equipment goes back to the ready state.
(5) To set it again, repeat step (2) to (4).
(6) Turn the power OFF.
<Confirmation>
If possible, perform a Fax transmission and check the adjusted density with the image on the recipient's
side.
Color
mode
Original mode
Item to be
adjusted
Remarks
Text/
Photo
Text * Photo
Black 7533 7534 7535 Manual density
center value
The larger the value is, the darker the image
becomes.
Acceptable values: 0 to 255 (Default: 128)
7542 - 7543 Automatic density
mode