6
© 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT
6 - 89
(7) When the adjustment is completed, press the [Button2] on the finisher control panel to store the
adjustment value in memory.
When the value is stored normally, the [LED1] on the control panel will blink for a number of times
that corresponds to the adjustment value set for the equipment.
See the following table for the number of times the [LED1] blinks and its corresponding
adjustment value.
(8) Turn OFF the power of the equipment.
(9) Turn OFF all bits of the SW1 on the Finisher control board.
(10) Install the board access cover.
Number of Blinking Adjustment Value
1-5
2-4
3-3
4-2
5-1
60
7+1
8+2
9+3
10 +4
11 +5