ERROR CODE AND TROUBLESHOOTING
8 - 17
C410 Fuser unit related
service call
Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
(e-STUDIO206L/256/306/356/456/506 only)
P. 8-169
C411 Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
(e-STUDIO207L/257/307/357/457/507 only)
P. 8-169
C412 Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
(e-STUDIO207L/257/307/357/457/507 only)
P. 8-169
C430 Thermistor abnormality: Abnormality of the thermistor is
detected after a specified period of time has passed from
power-ON (including ready state).
(e-STUDIO206L/256/306/356/456/506 only)
P. 8-170
C440 Fuser roller abnormality: The temperature of the fuser
roller has exceeded the range of control or does not even
reach the range.
(e-STUDIO206L/256/306/356/456/506 only)
P. 8-170
C443 Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
(e-STUDIO207L/257/307/357/457/507 only)
P. 8-172
C445 Thermistor or heater abnormality at power-ON:
Abnormality of service call the thermistor is detected
when power is turned ON or the temperature of the fuser
roller does not rise in a specified period of time after
power is turned ON.
(e-STUDIO207L/257/307/357/457/507 only)
P. 8-172
C447 Thermistor or heater abnormality: Abnormality of service
call the thermistor is detected or the temperature of the
fuser roller does not rise in a specified period of time.
(e-STUDIO207L/257/307/357/457/507 only)
P. 8-172
C449 Fuser roller abnormality: The temperature of the fuser
roller has exceeded the range.
(e-STUDIO207L/257/307/357/457/507 only)
P. 8-173
C450 Thermistor abnormality during printing: Abnormality of the
thermistor is detected during printing.
P. 8-174
C452 Thermistor abnormality at ready state: Abnormality of the
thermistor is detected during ready state.
P. 8-174
C4B0 Fuser unit error counter abnormality P. 8-175
C4C0 Fuser unit new/old detection fuse abnormality P. 8-175
C550 Optional
communication
related service call
RADF I/F error: Communication error has occurred
between the RADF and the scanner.
P. 8-176
C551 Document feeder model detection error: An optional
document feeder that is not compatible to this equipment
is installed.
P. 8-176
C570 Communication error between Engine-CPU and CNV
board
P. 8-176
C580 Communication error between CNV board and finisher P. 8-177
C5A0 Circuit related
service call
EEPROM communication abnormality (LGC board) P. 8-179
C8E0 Optional
communication
related service call
ADF communication abnormality: The system has to be
stopped because the control abnormality occurred
P. 8-177
Error code Classification Contents Troubleshooting