3
© 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
OUTLINE OF THE MACHINE
3 - 13
S7 ADU-TR2-SNR
ADU entrance sensor
Detecting the transporting paper at
automatic duplexing unit entrance
section
Fig. 3-7
Fig. 3-8
35-15
S8 SFB-EMP-SNR
Bypass paper sensor
Detecting presence/absence of paper
on the bypass tray
Fig. 3-9 35-15
S9 2ND-FEED-SNR
2nd transport sensor
Detecting the transport paper and
jamming fed from the 2nd drawer or
PFP/LCF
Fig. 3-10 18-6
S10 CST1-NEAR-EMP-SNR
1st drawer paper stock sensor
Paper amount detection in the 1st
drawer
Fig. 3-10 16-18
S11 CST1-TRY-SNR
1st drawer tray-up sensor
Position detection of the lifting tray of
the 1st drawer
Fig. 3-10 16-18
S12 CST1-EMP-SNR
1st drawer empty sensor
Paper presence/absence detection in
the 1st drawer
Fig. 3-10 16-18
S13 CST2-NEAR-EMP-SNR
2nd drawer paper stock sensor
Paper amount detection in the lower
drawer
Fig. 3-10 16-18
S14 CST2-TRY-SNR
2nd drawer tray-up sensor
Position detection of the lifting tray of
the 2nd drawer
Fig. 3-10 16-18
S15 CST2-EMP-SNR
2nd drawer empty sensor
Paper presence/absence detection in
the 2nd drawer
Fig. 3-10 16-18
S16 1ST-FEED-SNR
1st transport sensor
Detecting the transporting paper and
jamming fed from the bypass, drawer,
ADU
Fig. 3-7
Fig. 3-8
21-14
S17 RGST-SNR
Registration sensor
Detecting the paper transport at the
registration roller section
Fig. 3-7
Fig. 3-8
21-14
S18 REV-SNR
Reverse sensor
Detecting the transporting paper at
the reverse section
Fig. 3-8 34-2
S19 TEMP/HUMI-SNR
Temperature/humidity sensor
Detecting the temperature and
humidity of the outside air taken into
the equipment
Fig. 3-6 4-16
S20 PLTN-SNR1
Platen sensor-1
Detecting the opening/closing status
of the platen cover or RADF
Fig. 3-3 15-13
S21 PLTN-SNR2
Platen sensor-2
Detecting the opening/closing status
of the platen cover or RADF
Fig. 3-3 15-13
SW1 MAIN-SW
Main power switch
Turning ON/OFF of the equipment Fig. 3-4 4-3
SW2 FRNT-COV-INTLCK-SW
Front cover interlock switch
Supplying or shutting off AC power to
the switching regulator
(voltagegenerating circuit interlocked
with these covers) according to the
opening/closing status of the front
cover (Cover open: Shut off)
Fig. 3-4 1-11
SW3 ADU-INTLCK-SW
ADU interlock switch
Supplying or shutting off AC power to
the switching regulator
(voltagegenerating circuit interlocked
with these covers) according to the
opening/closing status of the
automatic duplexing unit (Cover
ope
n: Shu
t off)
Fig. 3-4 5-18
Symbol Name Function Remarks P-I