ERROR CODE AND TROUBLESHOOTING
8 - 214
[CC80] Rear alignment motor abnormality
* You receive a [CC80] error when the [ED14] error occurs three times in succession.
MJ-1101/1107
MJ-1106/1108
[CC80] Front alignment motor (M2) abnormality
MJ-1032
Classification Contents
Finisher related service call Rear alignment motor abnormality: The rear alignment motor is
not rotating or the rear alignment plate is not moving normally.
Check Item Measure
Rear alignment plate If there is mechanical problem when the rear alignment plate is
moved, fix the mechanism.
Rear alignment motor (M10) Check the connectors and harnesses between the rear
alignment motor (M10) and the finisher control PC board
(CN10).
Replacement part Measure
Rear alignment motor (M10)
Finisher control PC board
Check Item Measure
Rear alignment plate If there is mechanical problem when the rear alignment plate is
moved, fix the mechanism.
Rear alignment motor (M6) Check the connectors and harnesses between the rear
alignment motor (M6) and the finisher control PC board (CN17).
Replacement part Measure
Rear alignment motor (M6)
Finisher control PC board
Error Timing of detection
Front alignment motor (M2)
Front alignment plate home position
sensor (S5)
The turning OFF of the front alignment plate home position sensor (S5)
is not detected when the front alignment plate is moved from a point
where this sensor is turned ON to one point where this sensor is turned
OFF after the front alignment motor (M2) has been driven at the
specified number of pulse.
The turning ON of the front alignment plate home position
sensor (S5) is not detected when the front alignment plate is
moved from a point where this sensor is turned OFF to one
point where this sensor is turned ON after the front alignment
motor (M2) has been driven at the specified number of pulse.
Probable cause Checking and measures
Front alignment motor (M2)
abnormality
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the motor.
Front alignment plate home position
sensor (S5) abnormality
Measure the voltage on TP15 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
5% when shielded. If the voltage
does not fall within the range mentioned, replace the sensor.