ERROR CODE AND TROUBLESHOOTING
8 - 240
[F124] Language DB damage error
[F130] Invalid MAC address
[F131] Error due to damage to filtering setting file
[F140] ASIC format error
Classification Error item
Other service call Login after the startup fails in any starting mode because
language management database is corrupted.
Check item Measures
Setting Delete the journal file: [5] + [C] + [START] -> 4. Initialize DB -
> 3. Language DB
If the recovery is still not completed, reinstall the master data
and application program.
P. 11-5 "11.2.2 Update procedure"
Classification Contents
Other service call This error occurs when the top 3 bytes of the MAC address is
not "00" "80" "91".
Check Item Measure
SYS board Replace the SYS board.
Replacement part Remarks
SYS board
Classification Contents
Other service call The filtering function is not working properly due to the
damage to the file for the filtering setting.
Check Item Measure
Setting 1. Check the bad sector of the HDD (08-9072). If the result is
NG”, replace the HDD.
Notes:
It may take more than 30 minutes to finish the
checking.
2. Perform [3] + [C] + [POWER] -> [3], and then reinstall the
HDD software.
Notes:
User data will be deleted when [3] + [C] + [POWER] ->
[3] is performed.
Replacement part Remarks
HDD
Classification Error content
Other service call ASIC formatting fails or memory acquiring fails when software
is formatted
Check Item Measure
SYS board Connector check
Board check

Table of Contents