9
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO182/212/242
PAPER FEEDING SYSTEM
9 - 19
9.5.12 Pickup roller
(4) Release 2 latches and take off the paper
empty sensor from the bracket.
Fig. 9-34
(1) Take off the drawer.
(2) Rotate the pickup roller shaft
counterclockwise to make the rubber surface
of the roller facing down.
Note:
Because the tension is applied to the pickup
roller shaft by the pickup clutch when it is
rotated counter-clockwise, be sure to hold
the shaft while replacing the roller.
(3) Push 2 latches each to take off 2 pickup
rollers.
Notes:
• Be sure to install the pickup roller in the
correct direction when reassembling it.
• When it is difficult to take off the pickup
roller, alternatively follow the procedure
below to remove it.
1. Take off the damp heater unit or
dummy plate.
P.9-18 "9.5.10 Damp heater unit
(DH3) / Dummy plate"
2. Take off 2 pickup rollers by releasing 2
latches each.
Fig. 9-35
Fig. 9-36
Bracket
Paper empty sensor
Pickup roller
Pickup roller