e-STUDIO182/212/242 © 2009 TOSHIBA TEC CORPORATION All rights reserved
FUSER / EXIT UNIT
12 - 16
12.6.4 Exit sensor (S5)
(5) Remove 1 clip and 1 bushing.
(6) Take off the exit roller by sliding it to the rear
side.
Fig. 12-15
(1) Take off the fuser/paper exit unit.
P.12-14 "12.6.1 Fuser / Exit unit"
(2) Release the stopper using a flathead
screwdriver.
Fig. 12-16
(3) Open the guide and slide it to the front side.
Then slide its rear hinge downward.
Note:
Keep the guide being slid to the front side
during the steps (3) and (4).
Fig. 12-17
Exit roller
Clip
Bushing
Stopper
Stopper
Guide
1