6
© 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT
6 - 17
[C] Image position adjustment of the primary scanning direction
<Procedure>
(1) Performs FS-05. (05 Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the rear side and its side
along the original scale on the left.
(3) Press [TEST COPY] [START] to make a copy at the mode of A3 (LD), 100% and the lower
drawer (Refer to *).
(4) Measure the distance B from the left edge of the paper to 10 mm of the copied image of the ruler.
(5) Check if the distance B is within the range of 10±0.5 mm.
(6) If not, use the following procedure to change values and repeat the steps (3) to (5) above.
FS-05 Key in the code [3030] [START]
(Key in a value (acceptable values: 0 to 255))
Press the [OK] button (stored in memory).
(“100% A” is displayed.)
* The smaller the adjustment value is, the more the image is shifted to the left and the distance
B becomes narrower. (approx. 0.0423 mm/step)
Fig.6-13
50 100 150 200
B
Feeding direction