e-STUDIO281c/351c/451c © 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
DEVELOPER UNIT
12 - 18
[A-5] Developer sleeve
(3) Remove 2 screws and take off the doctor
blade.
Fig. 12-20
(1) Discharge the developer material
( P.12-16 "[A-2] Developer material").
(2) Take off the right cover
( P.12-17 "[A-4] Doctor blade").
(3) Remove 3 screws. Disconnect 1 connector
and take off the front cover.
Fig. 12-21
(4) Remove 1 screw and take off the polarity
adjustment plate.
Note:
Before disassembling, record (mark if any)
the scale pointed by the polarity adjustment
lever. Then match the polarity adjustment
plate at the scale previously recorded when
reassembling.
(5) Remove 1 screw and take off the bracket.
Fig. 12-22
Screw
Doctor blade
Screw
Screw
Screw
Front cover
Screw
Bracket
Polarity adjustment plate