Fault clearance
Motor and gear unit
98
Operating instructions: Outfeed conveyor TS 4800
Version 3.6ENG, 27.01.2020
Motor and gear unit
Should the drive motor have a disturbance, please refer to the motor manu-
facturer's operating instructions for information on fault elimination.
The operating instructions for the motor are part of the installation.
Pneumatic faults
Detected disturbance Possible cause Remedial action
No swivel movement Leak in line system Have technical personnel
establish and eliminate
the problem
Foreign particles at pneumatic
cylinder
Remove foreign particles
Pneumatic cylindrical seals
worn
Replace pneumatic
cylinder
Compressed-air supply below
minimum pressure
Check compressed-air
supply and restore oper-
ating pressure, if neces-
sary
Valve does not switch Leak in line system Have technical personnel
establish and eliminate
the problem
Socket loose Screw socket tight
Valve de-energised Look for the cause, elimi-
nate fault
Compressed-air supply below
minimum pressure
Check compressed-air
supply and restore oper-
ating pressure, if neces-
sary
Exhaust air generates
noises
Silencer defective Replace silencer