D301087 0308 - BL20 CANopen 4-149
I/O-Module Objects
4
Object 6423
hex
- Analog Input Global Interrupt Enable
This object enables the option for generating an interrupt signal. If
the value of this object is set from the default setting FALSE to
TRUE, the transmitting of the analog input data (TPDOs) can be trig-
gered by means of an interrupt signal.
Table 90:
Objects 6423
hex
Feature Description/ Value
Name Analog input global interrupt enable
Object code VAR
PDO-mapping No
Sub-index 00
hex
Data Type Boolean
Access rw
Default value, BL20 FALSE