DocNo.FM0410issueM1Page18
ON
12345678
ON
12345678
ADDRESS
DIL SWITCH
LK3
LK2
LK1
OPTI ONS
DIL SWITCH
11.INTERCOMUNITDILSWITCHES&LINKSETTINGS
Beforefittingtheintercomfrontthe“Address”and“Options”DILswitchesmustbeset. ThejumperlinksLK1,LK2&LK3
mustalsobesetinthecorrectposition.
INTERCOM ADDRESS DIL SWITCH
TheintercomAddressmustbesetsequentiallyusingan8bitbinary
codestartingfrom“1”inthelowestflatnumberonthesite.
Note:binary“0”(allDILswitchessetOFF)isnotused.
INTERCOM OPTIONS DIL SWITCH
AnyadditionalequipmentconnectedtoanintercommustbeenabledviatheOptionsDILswitch.
Options
DILSwitchNo.
Function
Options
DILSwitch“OFF”
Options
DILSwitch“ON”
1 I/OExpanderUnit N/A N/A
2 DoorEntry/Strobe Disabled Enabled
3 DoorEntryInterface N/A N/A
4 PIR/DoorContact Disabled Enabled
5 IntercomMode Master Remote
6 PullcordType NormallyOpen NormallyClosed
7 NotUsed N/A N/A
8 NotUsed N/A N/A
Whendoorentry/strobeisdisabled(DILSW2OFF)intercomterminals18&19areenabledasfouradditionalalarminputs‐seeSection10.
INTERCOM LINKS
IntercomMode LK1 LK2 LK3
Standard A A A
N/ORelayOutputConnected B A A
DoorEntryPhoneConnected A A A
RemoteIntercomConnected A A B
Remote&PhoneConnected A A B
ConnectedasaRemote B B A
RELAY OUTPUT
ArelayoutputisavailableonintercomsWITHOUTadoorentrytelephone connected.TheN/Ocleancontactoutputcanbe
activatedbythemanager/controlcentrewhenaspeechchannelisopen.TheN/Ocontactsareonterminals16&17‐
contactrating:30VDC@500mA.
PROGRAMMING
ThetotalnumberofintercomunitsandtheirID’smustbesetinthe“GeneralSetup&TenantsUnitIdentity”programming.
SeetheAdventxtProgrammingManual(DocNo.FM0411).
BEEPING INTERCOMS
Ifanintercom“beeps”every10secondsthenitsIDhasbeensetgreaterthanthenumberofintercomssetinthesystem
programming.Ifanintercombeepseveryfewminutesitisnotreceivingdata(orthedataiscorrupt).
Address
DILSwitchNo.
ON=
BinaryCode
1 1
2 2
3 4
4 8
5 16
6 32
7 64
8 128