DocNo.FM0410issueM1Page31
21.DIGITALDOORPANELINSTALLATION
TERMINATION
SeeTynetecDrgNo.ZXT100sheet3fordetailedwiringconnections;


DOORPANELAMPLIFIERBOARD

LINK SETTINGS
LK1selectsastandardorfailsafelocktype;astandardlockrequirespowertounlock(failsecure)whereasafailsafelock
requirespowertolock(failopen).Seebelowforotherlinksettings.
LinkNo. LinkPosition“A LinkPosition“B”
A0436B‐LK1 fitforstandardlock fitforfailsafelock
A0436B‐LK2 noexpanderfitted expanderboardfitted
A0436B‐LK3 A00418typeexpander A00437typeexpander
A0436B‐LK4 normal notusedforAdventxt
A00418‐LK4 normal nospeechandnotones
Thelockreleasedurationissetinthe“DoorEntrySetup”programming;seethe AdventxtProgrammingManual(Tynetec
DocNo.FM0411).
8 WAY DIL SWITCH SETTINGS (SW2)
DILswitches1to4areusedtosetauniquedoorpanelID(1to16).DoorpanelID’smuststartfrom1andrunsequentially.
DILswitches5to8selectthedoorpanelfeaturesshouldallbeONforAdventxt.
DIL
SW
DoorPanelID
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1
OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON
2
OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON
3
OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON ON ON
4
OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON
5
ONforDigitalDoorPanel‐OFFforFunctionalDoorPanel
6
OFF AFButton
(Normal)
ON Concierge
Button
OFF AF&Concierge
Button
ON AdventXTManager
Button
7
OFF OFF ON ON
8
OFF=NoExpander‐ON=ExpanderBoardFitted
4 WAY DIL SWITCH SETTINGS (SW1)
DILswitches1to4arenormallyallOFF.SetDILSwitch1ONtodisablethevoicereassuranceandreverttostandard
reassurancetones.DILswitches3to4havenofunction.
Terminal Function Connection
IP1 PlayWelcomeMessage 0VTrigger
IP2 NoFunction NotConnected
RELAY Activatesfordurationofcall NotConnected
SP1
WardenCallLoudspeakerAudio
1pairCW1308to
AdventxtController
SP2
Mic WardenCallMicrophoneAudio
1wireCW1308to
AdventxtController
12V 12VDCSupplyforDoorPanel 2pairsCW1308to
AdventxtController
0V 0VSupplyforDoorPanel
TX+ RS485Data+ 1pairCW1308to
AdventxtController
TX RS485Data‐
C1 DoorEntryAudiotoDoor 1pairCW1308to
AdventxtController
C2 DoorEntryAudiotoPhone
CONC ConciergeCalloutput NotConnected
T/G Tailgateinput(N/C)
2pairsCW1308to
PTE&DoorContact
EXLK ExternalLockinput(N/O)
0V CommonforT/G&EXLKinputs
LKSP LockSupplyVoltage 1.0mmpairto
DoorLock
LKRT LockReturnVoltage
+ LockPowerSupply+12V 1.0mmpairtolocal
LockPSU
LockPowerSupply0V

Table of Contents