2.SYSTEMOVERVIEW
INTERCOM UNITS
Upto255intercomunitscanbeconnecte d onthesystemnetwork.Eachintercomcanhaveceilingpullcords,smoke
detectorsandPIR’s(foractivityorintrudermonitoring)connectedasstandard.Anadditional4inputsareavailableon
intercomswithoutadoorentrytelephoneconnected.
REMOTE INTERCOM UNITS
Oneremoteintercomcanbeconnectedperintercomifspeechisrequiredin2rooms.Remoteintercomsareavailablewith
orwithoutPA.
MANAGER/LIFT CALLPOINTS
Variousvandalresistantcallpoints(forexternaluse)andliftspeechunitsareavailable.Theseareaddressedasintercom
unitsandarethereforeincludedinthe255maxlimit.
RADIO DEVICES
Amaximumof16networkreceivers(whichcanincludeamaximumof12zonednetworkreceivers)canbeconnectedon
thesystem.Upto2048Altecradiodevicescanberegisteredpersite.Radiodevicesinclude;personalpendants,fall
detectors,flooddetectors,temperaturesensors,gasdetectors,COdetectors,etc.
STATUS MODULE
Onestatusmodulecanbeconnectedonthesystemnetwork.Thishasakeyswitch&LED’stoselectthesystemoperating
mode.Aminiatureprinterandupto16callerIDdisplaypanelscanbeconnectedtothestatusmodule.
MANAGERS DISPLAY PANEL
Onemanagersdisplaypanelcanbeconnectedonthesystem.Thisisawallmounted10.4”VGAtouchscreenmonitorto
displaycallinformationandthesystemstatus.Italsohasa1GBmemorytostoresystemevents.Thisrequiresconnection
totheAdventxtcontrollerandamainssupply.
DOOR ENTRY OPTION
Upto16digitaldoorentrypanelscanbeconnectedtothe Adventxtcontroller‐additionalPSU’swillberequiredfordoor
locks.Doorpanelshavea“Manager”buttonasstandard.WhereonetelephoneisconnectedperdwellingusetheZFT220,
iftwotelephonesarerequiredbothmustbeZFT221’s.Arangeofcombinedwardencall/doorentryintercomoptionsare
alsoavailable(ZXT280‐287).
PA OPTION
Apublicaddress(PA)optionisavailabletobroadcastgeneralannouncementsorafirealarmtonethroughallintercoms.
SpecialintercomswithPAfacilitymustbefittedandonePAamplifier&SMPSUisrequiredforevery80intercoms.Each
groupof80intercomsmustbeonaseparatenetworkleg.
DECT & FIXED TELEPHONES
AMatrixIPPBXisrequiredtointerfacetheKirk400/6500DECTtelephonesystemtotheAdventxtandanoutside
telephoneline.TheKirk400DECTsystemwillusuallycovermostinstallations,largeorcomplexsitesmayrequireKirk
6500.Theradiocoverageofbasestationscanbeincrease dwithrepeaters.TomaintainoperationoftheDECTsystem
duringamainsfailureanadditionalUPSisrequired.
BT LINE SELECTOR OPTION
Ifspecified,theAdventxtcanhave2dedicatedtelephonelines(primary&secondary)oraprimarylineand a secondary
GSMcellularterminalconnectedviaaBTlineselectorunit.Iftheprimarylinefailsthesecondaryline/GSMmodulewill
automaticallybeselected,oncetheprimarylineisrestoredthesystemwillautomaticallyswitchback.
ETHERNET INTERFACE OPTION
TheEthernetInterfaceKitwillstoreallsystemactivityfordownloadandanalysisusingTynetec’siCaresoftware.A
BroadbandconnectionwithafixedIPaddressisrequired.
REMOTE CONTROL CENTRE (PSTN ARC)
ThechosenPSTNAlarmReceivingCentremustsupportBS8521orTT92protocol.
DIGITAL COMMUNICATOR (IP ARC)
TheoptionalDigitalCommunicatorallowstheAdventxttoconnectwithanIPAlarmReceivingCentre.