DocNo.FM0410issueM1Page32
21.DIGITALDOORPANELINSTALLATION
PROGRAMMING
Thenumberofdoorpanels,AccessCodes,TradeTimesandCallTransferTimesmustbesetinthe“DoorEntrySetup”
programming‐seetheAdventxtProgrammingManual(TynetecDocNo.FM0411).
VOLUME ADJUSTMENT
The5potentiometersVR2‐VR6ineachdoorpanelareusedtoindependentlyadjusttheaudioleve lto/from thedoor
entryandwardencallsystem.Toreducefeedbackthedoorpanelmicrophonegainisautomaticallymutedwhenthe
personintheflat(orthewarden)speaks‐thespeedatwhichthismuteisappliedcanbeadjustedusingthe VOXsensitivity
pot(VR4).
PotNo. Function
VR2 audiotodoorentryphone
VR3 audiotodoorpanel(fromdoorentryphone)
VR4 doorpanelVOXsensitivityadjustment
VR5 audiotowarden
VR6 wardensaudiotodoor&voicemessages
Alladjustmentsshouldbemadecarefullytoachieveoptimumvolumewithoutfeedbackorecho.Calladoorentry
telephoneviathedigitalkeypadandadjustVR2/VR3/VR4.Pressthe“Manager” buttontocallthewardenandadjust
VR5/VR6.Asadjustmentsaremade,temporarilyreplacethepanelinthebackboxwhilstperformingthetestcall.
LCD CONTRAST
ThepotentiometerVR1onthedoorpanelboardisusedtoadjusttheLCDcontrast.
LOCK CONNECTION
Thelockreleaseisconnecteddirectlytothedoorpanellocksupply(LKSP)andlockreturn(LKRT)terminalsusingatleast
1.0mmdiametercable.
DOORPANEL“LKRT”
DCLOCKONLY 
DOORPANEL“LKSP”

DiodeType:1N4001orMOVType:GNR07D330K
IMPORTANT
AnMOVorreversebiasdiodemustbefitteddirectlyacrossallDClock
terminalstopreventbacke.m.f.fromthelockcoilcausingmalfunction
andpossiblelongtermdamagetothedoorpanelorcontroller.
EXLK CONNECTION
A“presstoexit”(PTE)buttonisusedtooverridethelockandallowegressfromthebuilding.ThePTEbuttonshouldbe
momentaryactionwithbothN/OandN/Ccontacts.TheN/Ocontactsareconnectedacross0V&EXLKinthedoorpanelto
provideafixed10secondtimedlockrelease.WithconstantlyenergisedlocksitisrecommendedthattheN/Ccontactsare
alsoconnectedinserieswiththelocksupplytoprovidefailsafeoperationofthelock.
T/G CONNECTION
AN/Cdoorcontactcanbeconnectedacross0V&T/Ginthedoorpaneltodetectwhenthe entrancedoorisopened.
Whenthecontactsopenthelocktimeiscurtailedtoreducethelikelihoodofothervisitorsenteringduringthesamelock
releaseperiod(ie.tailgating).Thetelephone“dooropen”LED’swillilluminategreenwhenthedoorisopenifenabledin
the“DoorEntrySetup”programming.IfadoorcontactisnotfittedthentheT/Gterminalmustbelinkedto0V.