DocNo.FM0410issueM1Page24
PRINTER
ONSITE
FAULTS EXIST
CALL IN PROGRESS
LOCAL
OFFSITE
REMOTE
OFFSITE
ADVENTxt
0V
24V
0V
TX
RX
RST
TX-
TX+
0V
DA-
DA+
CL-
CL+
17.STATUSMODULEINSTALLATION
TheAdventxtStatusModule(P/No.ZXT300)isnormallyfittedinthe Managersofficeand
providesthefacilitytomanuallyswitchthesystemoperatingmode.Green,amberandred
LEDindicatorsidentifythecurrentmode;undercertainconditionsthesystemmaychange its
modeautomaticallyi.e.anunansweredcallin
OnsiteModewillreverttoLocalOffsiteor
RemoteOffsiteafterapresetdelay.
Thered“FAULTSEXIST”LEDindicatorwillilluminateif;(i)anyintercomunitsornetwork
devicesare“parked”topreventfaultsrereportingor(ii)iftheequipmenttelephone lineis
disconnectedorgoesopencircuitpreventinglocal/remoteoffsitemodesfrombeing
selected.ThesystemFaultMemorycanbecheckedbydialling1008andlisteningtothe
message.
Thegreen“CALLINPROGRESS”LEDwillilluminatewhenthere’sacallisinprogress‐the
operatingmodecannotbechangeduntilthecallhasended.
OPERATINGMODEINDICATORS
MODESELECTIONKEYSWITCH
FAULT/CALLINDICATORS
DATA

PRINTERPORTPOWER
NETWORK CONNECTION
TheStatusModulerequiresapoweranddataconnectiontothesystemnetworkwiring‐depending onlocationitmaybe
simplertoconnectdirecttotheAdventxtcontrolleronitsown2pairCW1308cable.
PRINTER OPTION
AnAdventxtprinter(P/No.ZXT311)canbepluggedintotheStatusModuletorecordallsystemactivitywiththe time/date
ofeachevent.Note;theprintermodulealsorequiresa240VACmainssupplyfromastandard13Awallsocket.
TheprintercomescompletewithaplugtopPSUmodule,a1.5mcommslead,a34mthermalpaperrollandawall
mountingbracket.
Topreservepaper,eacheventisprintedonasinglelineoftextinthefollowingformat:
Prefix ID Level Date Time Mode
AL 0001 INTERCM 16/12 15:47 ON
e.g.intercomalarmfromflat1at15:47on16December‐systeminonsitemode.
ForfulldetailsofalltextabbreviationsseethePrinterUserGuide(TynetecDocNo.FM0416).
Forreplacement34metrethermalpaperrollsorderTynetecP/No.W00336.
PROGRAMMING
TheNetworkKeyswitchUnit(StatusModule)mustbeenabledinthe“GeneralSetup”programming‐seetheAdventxt
ProgrammingManual(TynetecDocNo.FM0411).