DocNo.FM0410issueM1Page36
ON
12345678
ON
12345678
ADDRESS
DIL SWITCH
OPTI ONS
DIL SWITCH
LK1
LK2
VOLUME
VR1
23.COMBINEDINTERCOMINSTALLATION
ADDRESS DIL SWITCH
ThecombinedintercomAddressmustbesetsequentiallyusingan
8bitbinarycodestartingfrom“1”inthelowestflatnumberonthesite.
Note:binary“0”(allDILswitchessetOFF)isnotused.
OPTIONS DIL SWITCH
AnyadditionalequipmentconnectedtoanintercommustbeenabledviatheOptionsDILswitch.
Options
DILSwitchNo.
Function
Options
DILSwitch“OFF”
Options
DILSwitch“ON”
1 I/OExpanderUnit N/A N/A
2 DoorEntryMode N/A N/A
3 DoorEntryInterface N/A N/A
4 PIR/DoorContact Disabled Enabled
5 IntercomMode N/A N/A
6 PullcordType NormallyOpen NormallyClosed
7 Trigger3ActiveIndication NoIndication GreenD/OLED+Tone
8 NotUsed N/A N/A
NormallyALLOptionsDILswitcheswillbeOFF.SetDILswitch4ONifaPIRisconnected.
LINK OPTIONS
IntercomMode LK1 LK2
Standard A A
RemoteIntercomConnected B A
RELAY OUTPUT
ArelayoutputisONLYavailableonaREMOTEINTERCOMconnectedasaslavetothecombinedintercom.TheN/Oclean
contactoutputcanbeactivatedbythemanager/controlcentrewhenaspeechchannelisopen.TheN/Ocontactsareon
terminals16&17‐contactrating:30VDC@500mA.
TRIGGER 3 OUTPUT
Anopencollectoroutputcanbeactivatedfor5secondswhentheOPENbuttonispressedontheRemoteControlwithno
othercallinprogress.Terminal16ofthecombinedintercomcanbeconnectedtoaTynetecA00073universalrelaytogive
acleancontactoutput.Thecleancontactscanbeusedtoreleasealocaldoorlock.IfDILswitch7is“ON”thegreenDoor
OpenLEDwillilluminateandatonewillsoundonthecombinedintercomwhentheTrigger3outputisactive.
PROGRAMMING
ThetotalnumberofintercomunitsandtheirID’smustbesetinthe“GeneralSetup&TenantsUnitIdentity”programming.
SeetheAdventxtProgrammingManual(DocNo.FM0411).
BEEPING COMBINED INTERCOMS
Ifacombinedintercom“beeps”every10secondsthenitsIDhasbeensetgreaterthanthenumberofintercomssetinthe
systemprogramming.Ifanintercombeepseveryfewminutesitisnotreceivingdata(orthedataiscorrupt).
REMOTE INTERCOMS
Oneremoteintercom(P/No.ZXT221/226)canbeconnectedpercombinedintercom,seetheAdventxtwiringdiagrams
DrgNo.ZXT100sheet5.IMPORTANT:combinedintercoms(ZXT280287)anddoorentrytelephones(ZXT220/221)
CANNOTbeconnectedasaremoteextension.
AddressDILSwitchNo. ON=BinaryCode
1 1
2 2
3 4
4 8
5 16
6 32
7 64
8 128