DocNo.FM0410issueM‐1Page52
32.KIRK400MULTICELLDECT
MATRIX CONNECTION
TheMatrixIPPBXinterfacestheAdventxttotheDECT;italsogivesaccesstoanoutsidelineandallowszoningofcalls.
24VDC‐connecttotheUPSviathein‐linePSUmoduleprovided.
CO1‐connecttotheAdventxtDECToutputusingtheRJ11/BTleadprovided.
CO2‐connecttoanexternallineusingthesecondRJ11/BTleadprovided.
SLT1‐connecttothefixedCLIdesktelephoneviaaBTmastersocket(Note:cutoneplugofftheRJ11/RJ11leadprovided).
ETHERNET‐connecttotheFastswitchPort9usingtheRJ45patchleadprovided.
‐connecttoasoundEarthterminalusingtheEarthwireprovided
TheMatrixisfactoryprogrammedsoallincominglinesringallextensions.Ifanincominglineistoringspecificextensions
thentheMatrixmustbereconfigured.
Note;intheeventofamainsfailurei.e.iftheUPSbatteriesrunflatorifaUPSisnotfitted,theMatrixconnectsCO1toSLT1
andtheAdventxtwillonlyringthefixedCLIdesktelephone.
KIRK 400 WIRELESS SERVER (MULTI CELL) PROGRAMMING
TheMatrixmusthaveitsIPaddresssetto192.168.0.2
TheKirk400WirelessServermusthaveitsIPaddresssetto192.168.0.3anditsRadioPartNumbersetto3.
AdditionalIP12ChannelBaseStationsmustIPaddressesset192.168.0.4/5/6andRadioPartNumbers4/5/6.
ADVENT xt PROGRAMMING
ThePBXRingmustbeenabledinthe“GeneralSetup”programming‐seetheAdventxtProgrammingManual(TynetecDoc
No.FM0411).
2 CHANNEL MULTI CELL REPEATERS
Amaximumofthree2ChannelMultiCellRepeaterscanbeconnectedtotheKirk400MultiCellWirelessServerplusthree
perIP12ChannelBaseStation(total12persite).Repeatersrequireapowerconnectiononly;theycommunicatewiththe
Server/BaseStationvialowpowerradiosignalsanddonotrequirealineconnection.TomaintainDECTcoverageduringa
mainsfailureallRepeatersmustbeconnectedtoabatterybacked12VDCPSU.SeeRepeaterDeploymentRulesonthe
followingpage.
REPEATER POSITIONING
BeforeinstallingpowercablestoRepeaterpositionsitisimportantthattheoptimumpositionforcoverageisestablished.
RegistertheRepeaterontotheWirelessServer/IPBase(seeKirkProgrammingKitbelow)thenwiththeRepeaterpowered
fromabatterywalkawayinthedirectionthatcoveristobeextended.WhentheredLEDontheRepeaterstartstoflashit
isoutofrangeandmustbemovedbacktowardstheWirelessServer/IPBasebyaminimumof5metresbeforeselectingits
finallocation.
REPEATER PROGRAMMING
AKirkProgrammingKit(P/No.ZCS729)isrequiredtoprogramRepeaters,thekitconsistsofadoubleadapterandcomms
lead–thelatestServiceToolPCsoftwareanduserguidecanbedownloadedfreeofchargefrom;
http://support.polycom.com/PolycomService/support/us/support/voice/dect/dect_base_stations.html
REPEATER POWER CONNECTION
Repeatersshouldbeconnectedusing 1.0mmpaircabling,ifCW1308isbeingusedthensparepairscanbe doubled ‐up
and/orloopedbacktoformaringcircuittoreducethevoltagedrop.
TypicallythemaximumdistancetoaRepeaterviaCW1308shouldnotexceed100metres.
Note:connecta
maximumof6Repeatersper12V2APSU.
Maximum12x2ChannelMultiCellRepeaters
(3perMultiCellWirelessServer+3perIP12ChannelBaseStation)
240V
AC
12VDCPSUincluding
Standb