EasyManuals Logo

UNI-T UTG9000T Series User Manual

UNI-T UTG9000T Series
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #149 background imageLoading...
Page #149 background image
UTG9000T Series Function Abitrary Waveform Generator
149
Appendix BPerformance Index
Unless otherwise stated, all of the performance index are guaranteed within the following two
conditions.
1. The waveform generator has been calibrated and in the calibration period.
2. The waveform generator shall operate continuously for more than 30 minutes at the specified
operating temperature (18~28)
All specifications are guaranteed except those marked “Typical value”.
Model
UTG9604T
UTG9404T
UTG9204T
Channel CH1/CH2 CH3/CH4 CH1/CH2 CH3/CH4 CH1/CH2 CH3/CH4
Maximum frequency 600MHz 200MHz 400MHz 160MHz 200MHz 120MHz
Sampling rate
2.5GSa/sCH1 and CH2 625MSa/s CH3 and CH4
Waveform Sine, Square, Ramp, Pulse, Harmonic, Noise, PRBS, DC, Arbitrary wave
Mode Continue, Modulate, Sweep, Burst, Frequency counter, Protocol
Modulation type
AMFMPMDSBAMQAMASKFSK3FSK4FSKPSKBPSK
QPSK
OSK
PWM
SUM
Waveform Characteristic
Sine Wave
Frequency range
Hz
600MHz
Hz
200MHz
1uHz
400MHz
Hz
160MHz
1uHz
200MHz
Hz
120MHz
Resolution 1uHz
Accuracy
±50ppm within 90 days
±100ppm within one year
18°C
28°C
Harmonic distortion
(Typical value)
CH1/CH2
Test termoutput power 0dBm
DC
10MHz
-65dBc
10MHz60MHz
-60dBc
60MHz
150MHz
-50dBc
150MHz200MHz
-40dBc
200MHz
600MHz
-28dBc
Harmonic distortion
(Typical value)
CH3/CH3
Test termoutput power 0dBm
DC
10MHz
-65dBc
10MHz60MHz
-60dBc
60MHz
100MHz
-55dBc
100MHz200MHz
-40dBc

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UTG9000T Series and is the answer not in the manual?

UNI-T UTG9000T Series Specifications

General IconGeneral
BrandUNI-T
ModelUTG9000T Series
CategoryPortable Generator
LanguageEnglish