98
Maintenance Schedule
We recommend the following schedule:
As necessary
• Clean engraving table
• Clean main enclosure
• Clean top door window
Every 8 hours of engraving
• Clean X-Axis and Y-Axis bearings
• Clean X-Axis and Y-Axis rails and bearing
tracks
• Clean X-Axis belt
• Check beam window, #2 mirror, #3 mirror
and focus lens for debris. Clean ONLY if
dirty.
Every month
• Clean cooling fan filters
• Clean Z-Axis lead screws with white lithium
grease
• Check for X-Axis and Y-Axis belt wear.
Replace as necessary.
• Check and/or clean X-Axis and Y-Axis drive
gears
• Check for X-Axis and Y-Axis bearing wear.
Replace as necessary.
• Inspect system for loose screws and
mechanical parts. Tighten if necessary.
Every 6 months
• Clean exhaust plenum
Note: If you have any questions about maintaining the laser system, please contact the ULS Support Team.