4
vacon • 47 User Interfaces
A.1 (text keypad). This means that the target input for the analogue frequency reference signal
AI1 is now the analogue input in terminals 2/3. Whether the signal is voltage or current, must
be determined with the
dip switches. See the Installation manual for more information.
This is what is shown in the parameter list on page 81:
Assume you need to change the selected input. Instead of AI1 you wish to use the analogue in-
put on your option board in slot D. Do as instructed here:
Figure 19. Programming analogue inputs with graphical keypad
Figure 20. Programming analogue inputs with text keypad
Code Parameter Min Max Unit Default ID Description
P3.5.2.1.1 AI1 signal selection
AnIN
SlotA.1
377
Connect the AI1 signal to the
analogue input of your choice
with this parameter.
Programmable. See page 81.
PROGRAMMING INSTRUCTIONS
Graphical keypad Text keypad
1. Select the parameter and push the
Arrow
right
button.
1. Select the parameter and push the
OK but-
ton.
2. You are now in the
Edit mode as the slot
value
AnIN SlotA. is blinking and under-
lined.
2. You are now in the
Edit mode as the letter A
is blinking.
3. Push the
Arrow up button once to change
the slot value to
AnIN SlotC. Confirm with
OK button.
3. Push the
Arrow up button once to change
the slot value to
C. Confirm with OK button.