vacon • 65 Monitoring Menu
5.1.11 Solar
V2.12.7 FB data in 5 1 880 Raw value of process data in 32-bit signed format
V2.12.8 FB data in 6 1 881 Raw value of process data in 32-bit signed format
V2.12.9 FB data in 7 1 882 Raw value of process data in 32-bit signed format
V2.12.10 FB data in 8 1 883 Raw value of process data in 32-bit signed format
V2.12.11 FB Status Word 1 864
Fieldbus status word sent by application in bypass
mode/format. Depending on the FB type or profile
the data can be modified before sent to the FB.
V2.12.12 FB Speed Actual 0.01 865
Actual speed in %. 0 and 100% correspond to min-
imum and maximum frequencies respectively.
This is continuously updated depending on the
momentary min and max frequencies and the out-
put frequency.
V2.12.13 FB data out 1 1 866 Raw value of process data in 32-bit signed format
V2.12.14 FB data out 2 1 867 Raw value of process data in 32-bit signed format
V2.12.15 FB data out 3 1 868 Raw value of process data in 32-bit signed format
V2.12.16 FB data out 4 1 869 Raw value of process data in 32-bit signed format
V2.12.17 FB data out 5 1 870 Raw value of process data in 32-bit signed format
V2.12.18 FB data out 6 1 871 Raw value of process data in 32-bit signed format
V2.12.19 FB data out 7 1 872 Raw value of process data in 32-bit signed format
V2.12.20 FB data out 8 1 873 Raw value of process data in 32-bit signed format
Table 43. Solar monitoring items
Code
Monitoring
value
Unit Scale ID Description
V2.15.1 Vmp ref V 1914 DC voltage reference for MPP regulation
V2.15.2 Vmp ref correct V 1942
Present correction on DC voltage reference
(P&O + oscillation)
V2.15.3 Motor Power kW 1938 Motor shaft power
V2.15.4 Energy counter MWh 1937 Counter of energy taken by the supply
B2.15.5
Energy counter
reset
1932 To reset V2.15.4
Table 42. Fieldbus data monitoring
Code
Monitoring
value
Unit Scale ID Description