4
vacon • 55 User Interfaces
4.4.1 Relay and thermistor input terminals
4.4.2 Safe Torque off (STO) terminals
For more information on the functionalities of the Safe Torque Off (STO), see Vacon 100X In-
stallation Manual.
Table 32. I/O terminal signals for relay and thermistor terminals and connection example.
Relays and thermistor
Terminal Signal
21
RO1/1
Relay output 1
22
RO1/2
23
RO1/3
24
RO2/1
Relay output 2
25
RO2/2
26
RO2/3
28
TI1+
Thermistor input
29
TI1-
Table 33. I/O terminal signals for the STO functions.
Safe Torque Off terminals
Terminal Signal
S1
Isolated digital input 1 (inter-
changeable polarity);
+24V ±20% 10...15mA
G1
S2
Isolated digital input 2 (inter-
changeable polarity);
+24V ±20% 10...15mA
G2
F+
Isolated feedback (CAUTION!
Polarity to be respected);
+24V ±20%
F-
Isolated feedback (CAUTION!
Polarity to be respected);
GND
From
standard I/O
From term.
#13
From term.
#6
RUN