EasyManuals Logo

Visonic POWERMASTER 10 Installer's Guide

Visonic POWERMASTER 10
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide 99
APPENDIX E. Event Codes
E1. Contact ID Event Codes
Code Definition
Code Definition
101
Emergency
344
RF receiver jam detect
110
Fire
350
Communication trouble
114
Heat
351
Telco fault
120
Panic
373
Fire detector trouble
121
Duress
380
Sensor trouble
122
Silent
381
Inactive e
vent
123
Audible
383
Sensor tamper
131
Perimeter
384
RF low battery
132
Interior
393
Fire detector clean me
134
Entry/Exit
401
O/C by user
137
Tamper/CP
403
Auto arm
139
Burglary verified
406
Cancel
151
Gas alarm
408
Quick arm
152
Freezer al
ert
426
Door open event
154
Flood alarm
441
Armed home
158
High temperature
454
Fail to close
159
Low temperature
455
Fail to arm
180
Gas trouble
456
Partial arm
301
AC loss
459
Recent close event
302
Low system battery
570
Bypass
311
Battery
disconnect
602
Periodic test report
313
Engineer reset
607
Walk test mode
321
Bell
641
Senior watch trouble

Table of Contents

Other manuals for Visonic POWERMASTER 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMASTER 10 and is the answer not in the manual?

Visonic POWERMASTER 10 Specifications

General IconGeneral
Communication ProtocolsPowerG
Frequency433-434 MHz, 868-869 MHz
System TypeWireless
CommunicationGSM
Remote ControlYes
Event Log1000 events
Partitions3
Humidity85% non-condensing
User Codes8
Backup BatteryNi-MH battery pack
Operating Temperature-10°C to +50°C

Related product manuals